"GE MAX" is a product line used by GE primarily for blood glucose monitoring systems and test strips. Other "Max" related products include sealants, field-of-view technology for CT scanners, and industrial software solutions.
Feel confident using the stylish, intuitive interface of the Max. This sleek, dark package featuring a wide HCT range, auto-coding, status markers and ketone alerts can keep any user informed and in control.
| Test strip | Max Strip | |
|---|---|---|
| Coding | Auto-coding | |
| Enzyme / Measurement technology | GDH / Electrochemical sensor | |
| Blood sample source | Capillary, venous, arterial and neonatal whole blood | |
| Minimum sample volume | 0.75 µL | |
| HCT range | 10 - 70% | |
| Measuring range | 0.6 - 33.3 mmol/L (10 - 600 mg/dL) | |
| Meter dimensions (L x W x H) | 82.0 x 50.0 x 15.5 mm (3.23 x 1.97 x 0.61 inch) | |
| Display area (L x W) | 40.7 x 40.2 mm (1.60 x 1.58 inch) | |
| Weight (with battery) | 59.0 ± 5 g | |
| Power supply | 1 × CR2032 battery for Max | 2 × CR2032 batteries for Max Plus | |
| Memory capacity | 500 test results with date and time | |
| Operating temperature | 6 - 44°C (43 - 111°F) | |
| Operating relative humidity | 10 - 90% | |
| Meter storage conditions | -10 - 60°C (14 - 140°F) | |
| Test strip storage conditions | At 4 - 30°C (39 - 86°F), and below 90% relative humidity | |
| Bluetooth version (For Max Plus) | 4.0 | |
| Accuracy | For glucose concentrations < 5.5 mmol/L (100 mg/dL), 95% of measured glucose values within ± 0.83 mmol/L (15 mg/dL) of reference measurements. For glucose concentrations ≥ 5.5 mmol/L (100 mg/dL), 95% of measured glucose values within ± 15% of reference measurements. | |
| Precision | For glucose concentrations < 5.5 mmol/L (100 mg/dL), SD < 0.28 mmol/L (5 mg/dL) For glucose concentrations ≥ 5.5 mmol/L (100 mg/dL), CV < 5% | |
Fully compliant with ISO 15197:2013. (For other received credentials, please contact us.)
Accepts HCT 10-70%
Set blood glucose targets and customize your measurement schedule.
Note exercise and meal times.
Add notes, photos and status indicators for more complete entries.
Warning displayed when ketone levels need to be checked.
Useful data presented clearly.
Insert the strip into the socket of the meter. Calibration will occur automatically.
Touch a blood sample against the sample entry port of the strip.
After 5 seconds, the test result will appear.
Rotate and pull upwards to remove the test strip.
| Test strip | Max Strip | |
|---|---|---|
| Coding | Auto-coding | |
| Enzyme / Measurement technology | GDH / Electrochemical sensor | |
| Blood sample source | Capillary whole blood drawn from fingertip, palm or forearm, as well as venous, arterial and neonatal whole blood samples | |
| Minimum sample volume | 0.75 microliters | |
| HCT range | 10 - 70% | |
| Measuring range | 0.6-33.3 mmol/L (10 - 600 mg/dL) | |
| Meter dimensions (L x W x H) | 82.0 x 50.0 x 15.5 mm | |
| Display area (L x W) | 40.7 x 40.2 mm | |
| Weight (with battery) | 59.0 ± 5 g | |
| Power supply | 1 × CR2032 battery for Max | 2 × CR2032 battery for Max Plus | |
| Memory capacity | 500 test results with date and time | |
| Operating temperature | 6 - 44°C (43 - 111°F) | |
| Operating relative humidity | 10 - 90% | |
| Meter storage conditions | -10 - 60°C (14 - 140°F) | |
| Test strip storage conditions | At 4 - 30°C (39 - 86°F), and 10 - 90% relative humidity | |
| Bluetooth version (For Max Plus) | 4.0 | |